Click the Save and Close button to save the custom results settings, i.e., which objects, fields and records are to be kept during the solution in this case bus voltages.
![how to add bus feild in power world simulator how to add bus feild in power world simulator](https://images.slideplayer.com/22/6371700/slides/slide_31.jpg)
Set this field to YES for the buses that you want to save. Results will be saved only for those buses that have the Time Selected field on the grid set to YES. Find the Per Unit Voltage field and Add this to the list of Selected Fieldsand then click OK when done modifying fields. In this dialog select the Buses page and click the Add/Remove Fields button to bring up the list of Available Bus Fields. We specify what quantities we want to store as results for each object by clicking the View/Modify button, which brings up the Custom Results Selection Dialog. In this example we want to analyze the bus voltage magnitudes.
![how to add bus feild in power world simulator how to add bus feild in power world simulator](https://powersimtech.com/wp-content/uploads/2021/11/Design-Verification-Thumbnail.png)
This page contains grids for many devices including Generators, Lines, etc. For this reason, the Time Step Simulation tool allows you to explicitly specify what quantities you want to display and store. Obtaining solutions for a large number of time points has the potential to create unnecessary burden in memory and storage due to the large amount of data that can be generated. Now you can specify the hourly MW values for those loads. Then press the blue Arrow Button to pass the selected loads to the right side of the selector. You can press the shift key to select multiple elements. In the selector component, select the load for which you want to specify hourly values. Right-click on the grid and select Time Point Records > Insert/Scale Load Column(s) to bring up the Insert/Scale Column Dialog. In order to specify hourly load values you have to insert a column for each load. In this example your input data corresponds to hourly loads. Input data is specified on the Input Page. This will insert 24 time points, one for each hour starting tomorrow at 12:00 AM. Assume the other default values are acceptable and click OK. Set the field Total Number of Timepoints to Enter to 24. In this dialog, select tomorrow’s date from the drop down calendar component. In order to create a list of points, right-click on the Summary page and select Insert New Timepoint(s), which brings up the New Timepoint Dialog. As an example, we will assume that you have hourly load data for tomorrow and that you want to determine the system bus voltages for each hour. The Summary page is used to define and control the time points you want to analyze. The Time Step Simulation dialog is displayed when you access the Time Step Simulation by selecting Time Step Simulation from the Run Mode ribbon group on the Tools ribbon tab. Type RIGHT to include the numbers in the row to the right of the cell you’re in.This topic will get you started with using the Time Step Simulation tool and help you become familiar with the basics of setting up a time step simulation run. Type BELOW to include the numbers in the column below the cell you’re in. Type LEFT to include the numbers in the row to the left of the cell you’re in. Type ABOVE to include the numbers in the column above the cell you’re in. Then click the Paste function box and click the function you want.īetween the parentheses, type which table cells you want to include in the formula, and then click OK: In the Formula box, delete the SUM formula, but keep the equal sign (=). On the Layout tab (under Table Tools), click Formula.
![how to add bus feild in power world simulator how to add bus feild in power world simulator](https://media.cheggcdn.com/study/a08/a083b27e-fd21-4a80-828f-e829707197ce/7760-6-59P-i2.png)
Word includes other functions for tables-for example, AVERAGE and PRODUCT.Ĭlick the table cell where you want your result. For example, you can add up each row of numbers in the right-hand column, and then you can add up those results at the bottom of the column. You can use more than one formula in a table.
How to add bus feild in power world simulator update#
Tip: If you change any of the numbers you’re adding, select the sum and press F9 to update the total.